• Skip to primary navigation
  • Skip to main content
PM TRONICS Advanced Access Control Company Logo

PM TRONICS, INC.

Advanced Access Control

  • Home
  • About Us
    • PMT Security Blog
  • Products
    • OMNIA Access Control
    • Video Surveillance
      • Cathexis
      • Security Cameras
    • Biometrics
  • Solutions
    • Campgrounds
    • Educational Institutions
    • Retirement Communities
  • Support
    • Knowledgebase
    • Download Center
    • License Request
  • Our Integrators
  • Contact Us

AmanoDVMS

Which AmanoDVMS ports need to be open on my firewall?

Which AmanoDVMS ports need to be open on my firewall?

It is highly recommended that you isolate the camera and viewing networks by way of physical separation, or a VLAN network. You must open the following ports on your network for the system to function properly.

System Ports

In all AmanoDVMS installations, the following TCP ports must be open on all servers for the applications and servers to function correctly:

Port 5008

For signaling between SMServer and client applications, and inbound communications from clients to the SMServer

Port rule: open inbound

Port 5009

For remote connecting between DVRServer and client applications, and signaling between SMServer and DVRServer for time synchronization, setting changes, event information, etc.

Port rule: open inbound

Port 5010

For Watchdog monitoring communication between WDServer, client applications and DVRServer

Port rule: open inbound

Port 5011

For streaming between the Streaming Service and client applications

Port rule: open inbound

WebClient, Spotter Mobile and GatewayServer specific ports:

Ports 9000 and 9999

Between WebClient / Spotter Mobile and GatewayServer.

Port rule: open inbound

Agile Virtual Matrix specific ports:

Port 8084

Between SMServer and the Spotter for Windows client

Port rule: open inbound

Cameras can use the following ports in their operation:

HTTP Port 80

Default port for HTTP traffic, used by some cameras for communications

HTTP Port 8080

Used by some cameras for PTZ control communications

HTTPS Port 443

Default port for HTTPS traffic, used to securely communicate with a camera’s system

RTSP Port 554

Default port used on the VMS to traffic stream control signals

RTSP port 7070

Default stream control port for some camera drivers

UDP Ports 3556-4556

Used on the VMS to receive feeds from the cameras. Each video stream occupies two sequential ports in the port range.

Need further assistance?

Submit a Support Ticket

Submit a Support Ticket

FAQ

General

Can I initiate RS485 comms to a terminal from an existing IP terminal?

How to Select the Right Cable for the job

Network Configuration – Best Practices

Technical Bulletins

OMNIA Run as a Service fix for v4.x

Access Control

AmanoNet

AmanoNet Back up using IB Console

AmanoNet Minimum PC Requirements and Specifications

AmanoNet System Migration Notes

Archive Tagholders in AmanoNet

Archive Transactions in AmanoNet

AutoID IP Hardware in AmanoNet

How to move AmanoNet Access Control System from one PC to another (Firebird)

NOTICE! UPGRADE TO AMANONET 7.74 – EC2/400i NO LONGER AVAILABLE

Preparing IDEMIA Sigma Lite Readers for use in Nexus220 and AmanoNet (Legacy Mode)

Replace 400i Controller over Ethernet

Nexxus220

Change Default Password in Nexus220
Database Migration from Nexus220/IXP220 to OMNIA
How to fix a Java SE Binary Error in Nexus220 Software
How to get a copy of a database from Nexus220 Software
How to move Nexus220 to a different PC
Move Nexus220 Access Control System from one PC to another (Firebird)
Nexus220 Firmware Upgrade
Nexus220 The number of doors for this license has been exceeded
Preparing IDEMIA Sigma Lite Readers for use in Nexus220 and AmanoNet (Legacy Mode)
Reduce length of time on buzzer for readers in Nexus220
Replacing Nexus220 Controller with APC Controller and Wiegand Reader Module
Using Contextual Help and Key Assist For Nexus220

Omnia

Adding Widgets to the OMNIA Dashboard

Basic Trouble Shooting OMNIA

Batch Operations OMNIA

Change SYSDBA Password in OMNIA

Configuring Web Session Timeouts in OMINA

Create a Database for OMNIA 4.5 After Running the .iso

Create a Site Lockdown Input for OMNIA

Creating an Input on a Wiegand Reader Module to Generate a Lockdown/Emergency Mode For a Single APC Controller In OMNIA

Creating Operator Profiles

Creating Relay Actions I/O in OMNIA

Omnia Lite

Convert a Nexus Lite Database into OMNIA Lite Database

OMNIA LiTE Backup

PM Tronics Hardware

Amano Readers and Credentials

Change Modulation mode on XQT904 Quad Transmitter
How do I change Wiegand Output Mode on Amano readers?

Legacy Hardware

Factory Reset legacy Amano IP Cameras (sold prior to 2018)

Factory Reset Nexus220 controller

How do I factory reset the EC2 (400i) controller?

Setting IP on PMTronics Inc. Access Control Hardware

Partner Products

Partner Products

Preparing IDEMIA Sigma Lite Readers for use in Amano SW

Setting Read Range on a Conekt Reader

Video Management Systems

Cathexis Video (Amano Vision)

Cathexis Video AV (AntiVirus Exceptions)

AmanoDVMS

Vision

AmanoVision web access user name case sensitivity usage

PM Tronics offers complete security solutions and customized software built to exceed industry standards. We offer products that are easy to use and easily integrate with third party products and services. Learn More

PM TRONICS, INC.

Copyright © 2023 PM Tronics, Inc. | All Rights Reserved